Sealed AGM batteries

Sealed AGM batteries absorb sulfuric acid into a glass-fibre mat (Absorbed Glass Mat) in valve-regulated (VRLA) 12V lead-acid construction. This page maps Nova’s AGM range for UPS, security and lighting backup. Capacity is not recommended until load power and backup runtime are known. Code scanning lives on the models index. Flooded PzS, solar partial-state-of-charge storage and start-stop OEM fitment are not this family.

Longer warranty. Clearer trust.

Nova SDB-5512 sealed AGM battery product photograph

Available range

15 · 12 V · 5–200 Ah

  1. SDB-512
    Nova 12V 5–200Ah Sealed AGM battery15 modelsView products

Technical table

Conflict-free, source-backed catalogue rows. Capacity in Ah (C5 or C10 on the row), dimensions in mm, mass in kg. No stock or delivery claims.

Nova 12V 5–200Ah Sealed AGM battery

15 models
Nova 12V 5–200Ah Sealed AGM battery
CodeVoltage (V)Capacity (Ah)Length (mm)Width (mm)Height (mm)Weight (kg)
SDB-51212 V5 Ah (C10)90 mm70 mm106 mm1.8 kg
SDB-71212 V7 Ah (C10)151 mm65 mm97 mm2.1 kg
SDB-91212 V9 Ah (C10)151 mm65 mm97 mm2.5 kg
SDB-121212 V12 Ah (C10)151 mm99 mm98 mm3.5 kg
SDB-181212 V18 Ah (C10)181 mm77 mm169 mm5.4 kg
SDB-201212 V20 Ah (C10)181 mm77 mm169 mm5.6 kg
SDB-261212 V26 Ah
SDB-351212 V35 Ah (C10)195 mm130 mm180 mm9.2 kg
SDB-401212 V40 Ah (C10)197 mm165 mm170 mm12.2 kg
SDB-551212 V55 Ah (C20)
SDB-651212 V65 Ah (C10)350 mm166 mm178 mm19.5 kg
SDB-801212 V80 Ah (C10)261 mm174 mm220 mm22.5 kg
SDB-1001212 V100 Ah (C10)325 mm171 mm220 mm30.5 kg
SDB-1501212 V150 Ah (C10)495 mm175 mm230 mm48 kg
SDB-2001212 V200 Ah (C10)500 mm226 mm235 mm60 kg

Applications

Technology

Nova's AGM range serves backup-power applications — UPS, lighting, alarm/security and elevators — in a valve-regulated (VRLA) sealed construction, spanning 5 to 200 Ah. The commercial name “dry type” labels this sealed AGM range; electrolyte is held in the glass mat and water or acid is not added. Capacity selection is driven by the total load (W) to be backed up and the required backup runtime; a recommendation cannot be made before both are known.

How it works

Electrolyte is absorbed into a fiberglass mat (Absorbed Glass Mat) rather than held as free liquid, which minimizes gas emission during use and removes the need to add acid or water. The VRLA (valve-regulated) design includes a valve that vents gas safely once internal pressure crosses a set threshold; under normal use the valve stays closed.

Construction

Valve-regulated lead-acid (VRLA) sealed type; capacity values are stated at the C10 discharge rate.

Limitations

  • Before commissioning, the storage area must be cool, dry and protected against terminal short-circuit.
  • The charger must be set to a voltage profile matching VRLA/AGM chemistry; an incorrect profile can cause premature ageing.
  • Adding water or acid is neither required nor recommended — the VRLA construction is sealed.
  • Flooded PzS traction, solar partial-state-of-charge storage and start-stop OEM fitment are not this family.

Technical matching

Clarify the right family with application and critical dimensions, then request a qualified quote.

  1. 01

    Define the application

    Share equipment, duty cycle and operating environment.

  2. 02

    Confirm the dimensions

    Align capacity, voltage and critical measures together.

  3. 03

    Request a quote

    Route quantity and documentation needs to the right team.

Frequently asked questions

When is sealed AGM chosen instead of gel or traction?
AGM is the sealed VRLA backup-power family (UPS, security, lighting). Cyclic mobile gel and flooded PzS traction are separate families. Capacity is not recommended until load power and backup runtime are known.
How does Sealed AGM batteries work, and what does the range cover?
Electrolyte is absorbed into a fiberglass mat (Absorbed Glass Mat) rather than held as free liquid, which minimizes gas emission during use and removes the need to add acid or water. The VRLA (valve-regulated) design includes a valve that vents gas safely once internal pressure crosses a set threshold; under normal use the valve stays closed.
Which duty classes is Sealed AGM batteries evaluated for?
UPS (uninterruptible power supplies) Elevators Alarm and security systems Lighting systems Electric toy vehicles
What is the difference between the Sealed AGM batteries family page and the models list?
The Sealed AGM batteries family page explains the chemistry/construction class and the range map. Every model code, series group and technical row lives on that family's /models catalogue; exact dimensions and capacity are confirmed there and on series/SKU pages.
What limits apply when specifying Sealed AGM batteries?
Before commissioning, the storage area must be cool, dry and protected against terminal short-circuit. The charger must be set to a voltage profile matching VRLA/AGM chemistry; an incorrect profile can cause premature ageing. Adding water or acid is neither required nor recommended — the VRLA construction is sealed. Flooded PzS traction, solar partial-state-of-charge storage and start-stop OEM fitment are not this family.

Request a quote for this family.

Quote request

Call+90 544 800 10 01